Screw BIFIXE®

Compression screw

Indication:

True cervical femur fracture

The BIFIXE screw

The BIFIXE system allows compression of both fragments for true cervical fractures that are not or little displaced from the neck of the femur. This compression ensures a strengthening of the fractured area. This system does not puncture the external tissues while achieving a 20 mm recoil.

The installation of a BIFIXE system is performed only in the operating room using a specific ancillary device.

TECHNICAL FEATURES

Screw neck

• Anodized titanium • Barrel length: 40 mm

• Barrel diameter: 9.50 mm

• Net diameter: 11.90 mm

Screw body

• Anodized titanium

• Compression head screw, threaded over 20 mm and fitted with a pin suitable for sockets

• Screw body length: from 55 mm to 100 mm

• Body diameter: 6.50 mm

• Net diameter: 10.10 mm

BIFIXE system

• Anodized titanium

• Screw bodies delivered with screw head

• Compression 20 mm MAX

• System length: 75 mm to 120 mm

(TABLES OF REFERENCES PAGE 2)

Class IIb Medical Device

Before any use, read carefully the instructions on the instructions for use and on the label

FT/TR/02/A - Update : 09/01/2021

Manufacturer: I.CERAM

Tel : +33

(0)5 55 69 12 12

Parc Ester Technopole - 1 Rue Columbia

Fax : +33

(0)5 55 35 06 50

87068 Limoges Cedex

www.iceram.fr

Screw BIFIXE®

Compression screw

Indication:

True cervical femur fracture

REFERENCES

BIFIX screw neck

References

Length

TR03/1A/2/40

40 mm

Sterilization : Gamma radiation 25 kGy

BIFIXE screw body

References

Length

TR03/1A/1/55

55 mm

TR03/1A/1/60

60 mm

TR03/1A/1/65

65 mm

TR03/1A/1/70

70 mm

TR03/1A/1/75

75 mm

TR03/1A/1/80

80 mm

TR03/1A/1/85

85 mm

TR03/1A/1/90

90 mm

TR03/1A/1/95

95 mm

TR03/1A/1/100

100 mm

Sterilization : Gamma radiation 25 kGy

BIFIXE System (Assembled Neck and Screw Bodies)

References

Assembled length

Maximum compression

TR03/1A/40/55/75

75mm

TR03/1A/40/60/80

80 mm

TR03/1A/40/65/85

85 mm

TR03/1A/40/70/90

90 mm

TR03/1A/40/75/95

95 mm

TR03/1A/40/80/100

100 mm

20 mm

TR03/1A/40/85/105

105 mm

TR03/1A/40/90/110

110 mm

TR03/1A/40/95/115

115 mm

TR03/1A/40/100/120

120 mm

Sterilization: Gamma radiation 25 kGy

Class IIb Medical Device

Before any use, read carefully the instructions on the instructions for use and on the label

FT/TR/02/A - Update : 09/01/2021

Manufacturer: I.CERAM

Tel : +33 (0)5 55 69 12 12

Parc Ester Technopole - 1 Rue Columbia

Fax : +33 (0)5 55 35 06 50

87068 Limoges Cedex

www.iceram.fr

Attachments

  • Original Link
  • Original Document
  • Permalink

Disclaimer

I.Ceram SA published this content on 29 June 2023 and is solely responsible for the information contained therein. Distributed by Public, unedited and unaltered, on 29 June 2023 15:45:25 UTC.